Observe: Transformers cannot create energy; they only trade voltage for current.
Mode 2 · Four Major LossesMode 2: Core Loss Breakdown & Efficiency Active
Action: Inspect loss breakdown: Copper resistance (I^2*R), Eddy currents in iron, Magnetic Hysteresis, and Flux Leakage.
Observe: Practical transformer efficiency is typically high (95% - 98%).
Mode 2 · Laminated Core MitigationMode 2: Core Loss Breakdown & Efficiency Active
Action: Switch from solid iron core to laminated silicon steel sheets coated with varnish.
Observe: Laminations break eddy current loops, cutting core eddy losses by over 90%.
Mode 2 · Efficiency CurveMode 2: Core Loss Breakdown & Efficiency Active
Action: Calculate efficiency eta = P_out / P_in * 100% across load current.
Observe: Maximum efficiency occurs when variable copper loss equals constant core iron loss.
Mode 3 · Low Voltage Transmission DisasterMode 3: Long-Distance Grid Transmission Active
Action: Transmit 1 MW of power over 100 km grid lines (R_line = 10 Ohms) directly at 220 V.
Observe: Current required is 4545 A, causing I^2*R line loss = 206 MW! All power is lost as heat before reaching the town.
Mode 3 · High Voltage Step-Up SolutionMode 3: Long-Distance Grid Transmission Active
Action: Step voltage up to 220 kV (220,000 V) using a step-up transformer.
Observe: Line current drops 1000 times to just 4.55 A! Line loss drops by 1,000,000 times to just 207 Watts (< 0.03% loss)!
Mode 3 · Substation Step-DownMode 3: Long-Distance Grid Transmission Active
Action: Step voltage down at local substation back to 220 V for consumer safety.
Observe: This demonstrates why AC defeated DC in the historical 'War of the Currents'—transformers enable efficient long-distance power grids.
⏱ ~45s
🎉 Investigation Complete!
You've mastered all 3 key physical phenomena for this laboratory.
Investigation Mode
Transformer Core & Winding Parameters
220 V
100 turns
200 turns
44.0 Ω
98.5% Linkage
15.0 Ω
22.0 kW
Transformation Regimes
Simulation Playback & Speed
1.00×
Electromagnetic Principle
Mutual Induction in Iron Core: Alternating current in the primary coil induces a continuous harmonic magnetic flux $\Phi(t) = \Phi_m \sin\omega t$ threading the soft-iron core. By Faraday's Law, this identical core flux links every turn of both coils, establishing back EMF $e_p = -N_p \frac{\mathrm{d}\Phi}{\mathrm{d}t}$ and secondary induced EMF $e_s = -N_s \frac{\mathrm{d}\Phi}{\mathrm{d}t}$. For an ideal transformer, the voltage ratio strictly equals the turns ratio $\frac{V_s}{V_p} = \frac{N_s}{N_p}$. Conservation of energy ($P_{\text{in}} = P_{\text{out}}$) guarantees that stepping up voltage proportionally steps down current ($\frac{I_p}{I_s} = \frac{N_s}{N_p}$), preserving the product $V \cdot I$.
Ratio:2.00 : 1
Vs:433.4 V
|
Is:9.85 A
Flux:±9.9 mWb
Primary Coil ($N_p$)
Secondary Coil ($N_s$)
Soft-Iron Core
Magnetic Flux Streamlines ($\Phi_B$)
Drag: Rotate 3D View | Pinch/Scroll: Zoom
Transformation Ratio ($k = N_s/N_p$)2.00 × (Step-Up)
Secondary Voltage ($V_s$ RMS)433.4 V
Secondary Current ($I_s$ RMS)9.85 A
Primary Current ($I_p$ RMS)20.10 A
Transformer Efficiency ($\eta$)96.3%
Harmonic Mutual Waveforms • Primary vs. Secondary Waveforms
Physics is best learned through exploration, experimentation, and visualization.
Developed by Dr. Ajith S Kumar, Department of Physics, D B Pampa College, Parumala, this collection brings Plus Two (Class 11 & 12) physics to life through interactive simulations. Each simulation is carefully designed around the concepts students find most challenging, helping learners develop a deeper understanding rather than simply memorize formulas. Aligned with the Kerala Higher Secondary (SCERT) and NCERT syllabus, it is open to every student, teacher, and physics enthusiast.