Mode 1 · Forward Bias Circuit
Mode 1: Virtual Circuit Laboratory Active
Action: Connect diode with positive battery terminal to p-side and negative terminal to n-side.
Observe: External voltage opposes the built-in barrier, reducing depletion width and allowing current to flow in milliamps (mA).
Mode 1 · Reverse Bias Circuit
Mode 1: Virtual Circuit Laboratory Active
Action: Reverse battery connections: positive terminal to n-side, negative to p-side.
Observe: External voltage reinforces built-in barrier, widening depletion zone and dropping current to tiny microamps (uA).
Mode 1 · Meter Range Selection
Mode 1: Virtual Circuit Laboratory Active
Action: Notice ammeter scale switch: mA in forward bias vs uA in reverse bias.
Observe: Diode exhibits strong unidirectional conduction, functioning as an electrical one-way valve.
Mode 2 · Forward Knee Voltage
Mode 2: 4-Quadrant V-I Tracer Active
Action: Slowly increase forward voltage from 0 to 1.0 V.
Observe: Current remains negligible until Knee/Cut-in voltage (V_k ~ 0.7 V for Si, ~0.3 V for Ge), beyond which current rises exponentially.
Mode 2 · Reverse Saturation Current
Mode 2: 4-Quadrant V-I Tracer Active
Action: Sweep reverse voltage from 0 to -10 V.
Observe: Reverse current saturates at an almost voltage-independent tiny value I_0, driven entirely by thermally generated minority carriers.
Mode 2 · Reverse Breakdown
Mode 2: 4-Quadrant V-I Tracer Active
Action: Increase reverse voltage beyond breakdown voltage V_Z.
Observe: Current increases abruptly without further voltage increase due to avalanche multiplication or Zener quantum tunneling.
Mode 3 · Dynamic Resistance Formula
Mode 3: Dynamic Resistance (r_d) Active
Action: Pick an operating point Q on the forward curve and calculate r_d = Delta V / Delta I.
Observe: Dynamic resistance is the inverse slope of the V-I curve at that bias point.
Mode 3 · Forward vs Reverse Values
Mode 3: Dynamic Resistance (r_d) Active
Action: Compare forward r_d above the knee (typically 10 - 30 Ohms) with reverse r_d (typically MegaOhms).
Observe: Diode resistance drops by 5 to 6 orders of magnitude between reverse and forward conduction.
Mode 3 · Static vs Dynamic
Mode 3: Dynamic Resistance (r_d) Active
Action: Compare static resistance R_dc = V/I with dynamic resistance r_d = Delta V / Delta I.
Observe: Because the V-I characteristic is nonlinear, static and dynamic resistances are distinctly different at every point.
Mode 4 · Forward Barrier Lowering
Mode 4: Junction Microphysics Active
Action: Apply forward bias V_f and watch the energy band diagram.
Observe: Effective barrier height lowers to (V_0 - V_f), allowing exponential influx of majority carriers across the junction.
Mode 4 · Reverse Barrier Elevation
Mode 4: Junction Microphysics Active
Action: Apply reverse bias V_r.
Observe: Effective barrier height increases to (V_0 + V_r), completely choking majority carrier flow.
Mode 4 · Minority Sweeping
Mode 4: Junction Microphysics Active
Action: Track minority carriers entering the widened depletion zone under reverse bias.
Observe: The strong electric field immediately sweeps minority carriers across, generating the small reverse saturation current I_0.